كلية طب الأسنان||College of Dentistry
Permanent URI for this collectionhttps://repository.iau.edu.sa/handle/123456789/14
Browse
Browsing كلية طب الأسنان||College of Dentistry by Subject "3D printing"
Now showing 1 - 6 of 6
- Results Per Page
- Sort Options
Item Antibiofilm Activity of 3D-Printed Nanocomposite Resin: Impact of ZrO2 Nanoparticles(2023) Abdulrahman Khattar Alanzi; Alghafli, Jawad A.; Muheef, Mohammed A.; Husain muneer Mohammed Alshoalah; Al-Dubays, Mohammed A.; Mohammed Gad; Doaa AlEraky; Khan, Soban Q.; AlEraky, Doaa M.; Gad, Mohammed M.Poly(methyl methacrylate) (PMMA) is a commonly used material, as it is biocompatible and relatively cheap. However, its mechanical properties and weak antibiofilm activity are major concerns. With the development of new technology, 3D-printed resins are emerging as replacements for PMMA. Few studies have investigated the antibiofilm activity of 3D-printed resins. Therefore, this study aimed to investigate the antibiofilm activity and surface roughness of a 3D-printed denture base resin modified with different concentrations of zirconium dioxide nanoparticles (ZrO2 NPs). A total of 60 resin disc specimens (15 × 2 mm) were fabricated and divided into six groups (n = 10). The groups comprised a heat-polymerized resin (PMMA) group, an unmodified 3D-printed resin (NextDent) group, and four 3D-printed resin groups that were modified with ZrO2 NPs at various concentrations (0.5 wt%, 1 wt%, 3 wt%, and 5 wt%). All specimens were polished using a conventional method and then placed in a thermocycler machine for 5000 cycles. Surface roughness (Ra, µm) was measured using a non-contact profilometer. The adhesion of Candida albicans (C. albicans) was measured using a fungal adhesion assay that consisted of a colony forming unit assay and a cell proliferation assay. The data were analyzed using Shapiro–Wilk and Kruskal–Wallis tests. A Mann–Whitney U test was used for pairwise comparison, and p-values of less than 0.05 were considered statistically significant. The lowest Ra value (0.88 ± 0.087 µm) was recorded for the PMMA group. In comparison to the PMMA group, the 3% ZrO2 NPs 3D-printed group showed a significant increase in Ra (p < 0.025). For the 3D-printed resins, significant differences were found between the groups with 0% vs. 3% ZrO2 NPs and 3% vs. 5% ZrO2 NPs (p < 0.025). The highest Ra value (0.96 ± 0.06 µm) was recorded for the 3% ZrO2 NPs group, and the lowest Ra values (0.91 ± 0.03 µm) were recorded for the 0.5% and 5% ZrO2 NPs groups. In terms of antifungal activity, the cell proliferation assay showed a significant decrease in the C. albicans count for the 0.5% ZrO2 NPs group when compared with PMMA and all other groups of 3D-printed resins. The group with the lowest concentration of ZrO2 NPs (0.5%) showed the lowest level of C. albicans adhesion of all the tested groups and showed the lowest Candida count (0.29 ± 0.03). The addition of ZrO2 NPs in low concentrations did not affect the surface roughness of the 3D-printed resins. These 3D-printed resins with low concentrations of nanocomposites could be used as possible materials for the prevention and treatment of denture stomatitis, due to their antibiofilm activities.Item Comparative Evaluation of Surface Roughness and Hardness of 3D Printed Resins(2022) Leenah Alsulaimi; Alsulaimi, Leenah; Alotaibi, Reema; Alboainain, Areej; Haidar AlAlawi; Alshehri, Sami; Soban Q. Khan; Alsaloum, Mohammed; Abdulkareem AlHumaidan; Mohamed M Gad; Gad, Mohammed M.The effect of printing parameters on the surface characteristics of three-dimensional (3D)-printed denture base resins (DBRs) is neglected. Therefore, this study investigated the effect of printing orientation and post-curing time on the surface roughness and hardness. One conventional heat-polymerized (HP) resin and two 3D-printing resins (NextDent (ND) and ASIGA (AS)) were used to fabricate a total of 250-disc (10 × 2.5 mm) specimens. ND and AS specimens were printed with different orientations (0-, 45-, and 90-degree) and each orientation group was subjected to four post-curing times (30, 60, 90, 120 min). Printed specimens were thermo-cycled (10,000 cycles) followed by the measuring of surface roughness (Profilometer (Ra)) and hardness (a Vickers hardness (VH)). ANOVA and post hoc tests were used for data analysis (α = 0.05) at significant levels. AS and ND showed no significant changes in Ra when compared with HP (p ˃ 0.05), except the 45-degree orientation (AS/90 min and AS/120 min) significantly increased surface roughness (p ˂ 0.001). There was no significant difference in Ra with different orientations and post-curing time for both materials AS and ND (p ˃ 0.05). Compared with HP, 3D-printed DBRs showed low VH values (p ˂ 0.001). For AS, 90-degree orientation showed a significant decrease in VH at 60, 90, and 120 min when compared with 0- and 45-degree orientation (p ˂ 0.001), while ND showed no significant difference in VH with different printing orientations (p ˃ 0.05). The VH of AS and ND improved when increasing post-curing time to 120 min (p ˂ 0.001), and the printing orientations and post-curing time did not affect the Ra of 3D-printed DBRs.Item Effect of Denture Disinfectants on the Mechanical Performance of 3D-Printed Denture Base Materials(2023) Nora S. Alkaltham; Reem A. Aldhafiri; Al-Thobity, Ahmad M.; Soban Q. Khan; Aljubran, Hussain; Ijlal Shahrukh Ateeq; Khan, Soban Q.; Hussain Aljubran; Gad, Mohammed M.Denture care and maintenance are necessary for both denture longevity and underlying tissue health. However, the effects of disinfectants on the strength of 3D-printed denture base resins are unclear. Herein, distilled water (DW), effervescent tablet, and sodium hypochlorite (NaOCl) immersion solutions were used to investigate the flexural properties and hardness of two 3D-printed resins (NextDent and FormLabs) compared with a heat-polymerized resin. The flexural strength and elastic modulus were investigated using the three-point bending test and Vickers hardness test before (baseline) immersion and 180 days after immersion. The data were analyzed using ANOVA and Tukey’s post hoc test (α = 0.05), and further verified by using electron microscopy and infrared spectroscopy. The flexural strength of all the materials decreased after solution immersion (p < 0.001). The effervescent tablet and NaOCl immersion reduced the flexural strength (p < 0.001), with the lowest values recorded with the NaOCl immersion. The elastic modulus did not significantly differ between the baseline and after the DW immersion (p > 0.05), but significantly decreased after the effervescent tablet and NaOCl immersion (p < 0.001). The hardness significantly decreased after immersion in all the solutions (p < 0.001). The immersion of the heat-polymerized and 3D-printed resins in the DW and disinfectant solutions decreased the flexural properties and hardness.Item Fracture Load of 3D-Printed Interim Three-Unit Fixed Dental Prostheses: Impact of Printing Orientation and Post-Curing Time(2023) Alkhateeb, Reem I.; Rand Baher AlDamanhori; Hadeel Saud AlGaoud; Rand Rasheed AlShubaili; Mohammed Gad; Gad, Mohammed M.The fracture resistance of 3-unit interim fixed dental prostheses (IFDPs) fabricated using digital light processing (DLP) additive technology with different printing parameters is neglected. Therefore, this study investigates the effect of different printing orientations and different post-curing times on the fracture resistance of 3-unit IFDPs fabricated from two three-dimensional (3D) printed resins, NextDent, C&B (CB), ASIGA, and DentaTOOTH. A 3-unit dye was scanned, and an IFDP was designed. A total of 300 specimens (150/materials, n = 10) were printed and divided into three groups according to printing orientations (0°, 45°, 90°) per material. Each orientation was subdivided into five groups (n = 10) considering the post-curing time (green state as control, 30, 60, 90, and 120 min). All specimens underwent thermocycling (5000 cycles). Each specimen was fitted onto the die and loaded until fracture using a universal testing machine with a loading rate of 1 m/min. Data were analyzed using ANOVA and post hoc Tukey test (α = 0.05). The result showed that printing orientation had a significant effect on the fracture load for both ASIGA and NextDent materials (p < 0.05). The highest fracture load was recorded with 45° orientation, followed by 0° orientation and 90° orientation showed the lowest values per respective post-curing time. Post-curing time increased the fracture load (p < 0.05). Post-curing time had a positive effect on the fracture load. As the post-curing time increased, the fracture resistance load increased (p < 0.05), with 90 and 120 min showing the highest fracture load. The 0° and 45° printing orientations have a high fracture load for 3D-printed IFDPs, and an increased post-curing time is recommended.Item Influence of ZrO2 Nanoparticle Addition on the Optical Properties of Denture Base Materials Fabricated Using Additive Technologies(2022) Abdulrahman Khattar Alanzi; Alsaif, Majed H.; Ibrajim Almindil; Alshaikh, Ali A.; Alsalem, Ali M.; Almindil, Ibrahim A.; Abdullah Mohammed Ahmed Al-Ajwad; Ali Musallam Alsalem; Ali Jaffar Ahmed Alboori; Almuhanna, Hussain M; Khan, Soban Q.; Soban Q. Khan; Gad, Mohammed M.This study investigated the translucency of 3D-printed denture base resins modified with zirconium dioxide nanoparticles (ZrO2NPs) under thermal cycling. A total of 110 specimens were fabricated and divided into 3 groups according to the materials, i.e., heat-polymerized resin, and 3D-printed resins (NextDent, and ASIGA). The 3D-printed resins were modified with 0, 0.5, 1, 3, and 5 wt.% of ZrO2NPs. All the specimens were subjected to 5000 thermal cycles. The translucency was measured using a spectrophotometer. The results showed that the heat-polymerized resin had considerably higher translucency than the 3D-printed resins. Compared to the unmodified group, the translucency decreased significantly after adding 5% ZrO2NPs to NextDent and 3% ZrO2NPs to ASIGA resins. The highest translucency was achieved for NextDent by adding 0.5% ZrO2NPs and for ASIGA without any ZrO2NPs. It was found that the average concentration level in ASIGA was significantly higher than that in NextDent. These findings revealed that 3D-printed resins have lower translucency than heat-polymerized acrylic resin, and adding ZrO2NPs at low concentrations did not affect the translucency of the 3D-printed resins. Therefore, in terms of translucency, 3D-printed nanocomposite denture base resins could be considered for clinical applications when ZrO2NPs are added at low concentrations.Item The Effect of Salivary pH on the Flexural Strength and Surface Properties of CAD/CAM Denture Base Materials(2022) Alzaid, Maryam; AlToraibily, Fatemah; al-Qarni, Faisal D.; Al-Thobity, Ahmad M.; Mohammed Gad; Ali, Saqib; Saqib Ali; Gad, Mohammed M.Objectives This study aimed to evaluate the influence of different salivary pH on flexural strength, hardness, and surface roughness of computer-aided design and computer-aided manufacturing (CAD/CAM) milled and three-dimensional (3D)-printed denture base resins.Methods One heat-polymerized, two CAD/CAM milled (IvoCad, AvaDent), and two 3D-printed (FormLabs, NextDent) denture base resins were fabricated and divided into five groups (n = 10) according to the solutions: three groups were immersed in different salivary pH (5.7, 7.0, or 8.3), one group was immersed in distilled water (DW) as a positive control, and one group had no immersion (negative control). All immersions were performed at 37°C for 90 days. Flexural strength, hardness, and surface roughness were measured before and after immersion. Data was analyzed with analysis of variance and post hoc Tukey's test (α = 0.05).Results After immersion, all specimens had lower flexural strength values when compared with those with no immersion. Comparing the immersion groups, the highest flexural strength value (93.96 ± 3.18 MPa) was recorded with IvoCad after immersion in DW while the lowest value (60.43 ± 2.66 MPa) was recorded with NextDent after being immersed in 7.0 pH saliva. All specimens had significant decrease in hardness except IvoCad and AvaDent specimens where both presented the highest surface hardness (53.76 ± 1.60 Vickers hardness number [VHN]) after immersion in DW while NextDent showed the lowest hardness value (24.91 ± 2.13 VHN) after being immersed in 8.3 pH saliva. There was statistically significant difference between the baseline and different artificial salivary pH solutions in terms of surfaces roughness, with the highest surface roughness were found in 3D-printed resin materials.Conclusion After exposure to artificial saliva with different salivary pH, the milled CAD/CAM denture base resins showed higher flexural strength, hardness, and lesser surface roughness than conventional and 3D-printed denture base resins.
